Calibrators Series , Device and Accessories

Temperature sensors are subject to mechanical, thermal and chemical stress. This results in a drift the longer the sensors are in use. Only the regular calibration of the sensors provides information on the difference between the actual temperature and the measured temperature and makes the specific drift visible.

Dry block calibrators and micro calibration baths are used to check and calibrate a wide range of temperature measuring instruments and temperature sensors. Mechanical, electro-mechanical or electronic measurement equipment can be checked with ease. The compact and robust SIKA instruments are easy to transport, simple to use and offer all the features required for the specific test.

A temperature calibrator needs to meet a wide range of requirements: as a portable device, it has to cope with frequently changing operation locations in the test bay or in production, while being equally suitable for stationary use in the measuring workshop and testing and inspection laboratory. For this reason, the instruments must be lightweight and handy for quick and easy use on site. SIKA offers several temperature calibrators to cover the range from -55 °C to 1300 °C.

The following can be tested directly:

Contact-based immersion or surface temperature sensors
Sensors with special shapes and sizes
Non-contact infrared instruments and thermal imaging cameras

Test pumps and digital gauges

Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. 

However, the characteristics of the even best sensor or transducer can be altered by a wide variety of factors. This drift cannot be prevented, and it leads to incorrect readings. Calibration allows these deviations to be measured and documented in a certificate. All pressure measuring devices that significantly affect processes or activities should be calibrated before being used. SIKA‘s mobile test and calibration devices are effective aids for performing the necessary test and calibration tasks quickly.

 

Mono function / Multifunction Simulators

Monofunction simulators / Multifunction simulators

SIKA monofunction simulators offer exceptional performance, durability and reliability. Our temperature or current loop calibrators are compact, lightweight and easy to transport. These instruments feature rubber keys for ease of use and are insensitive to dust and splashing water. The tough plastic housing is resistant to shocks and impacts and offers additional protection against vibrations in harsh environments. Screened 4 mm sockets allow quick and easy connection of equipment to be tested.

SIKA multifunction simulators combine the functions of several devices in one instrument. These simulators are designed for easy generation and measurement of temperature, pressure, frequency and electrical signals. These documenting instruments have been developed for testing and calibration of numerous process signals as well as their generation and measurement with high accuracy. Operation is intuitive via keypad or pull-down menus.

 

Temperature Hand-held instruments

The handy and reliable instruments of the MH range are used for measuring and recording humidity, temperature or pressure. The MH range is very flexible and is equally suitable for simple measurements and special applications

Myan Steam offer calibration services for consistency and accuracy which can trust calibrator of SIKA Dr. Siebert and Kühn GmbH and Co. KG who has been licensed by DIN EN ISO/IEC 17025 from the Deutschen Kalibrierdienst (DKD) since 1995. 

Temperature calibration service 
Temperature Range from 0°C …… 160°C

Pressure calibration service
vacuum pressure ….. 600 barg

Electric values calibration service
Resistors and ohmmeters , 0 ….. 2 kΩ 
DC voltmeters , transmitters , 0 …. 20 VDC 
DC testing , measuring devices , (0)4…20 mA

With our network of Labs , we can offer calibration services Certified to ISO/IEC 17025 : 2005 and exproviding industrial services of Certified Body for ISO 9001 , ISO 14001 , GMP , HACCP . Training and  Consultant for academic seminars , Technical Documentation System , Test and Calibration of Measuring Equipment. Repair & inspection for test equipment in the laboratory with a 3 year repair result certificate 

 Accreditation ISO / IEC 17025: 2005 (ILAC) which consist large title of ;

 

  • Electrical & RF microwave
  • Temperature & Humidity
  • Dimension 
  • Optical & Chemical
  • Torque & Force
  • Pressure and Vacuum

 

Calibration Partners

SIKA Dr.Siebert and Kuhn & GmbH

DAkkS calibration certificate traceability of measured values to approved (national) standards as specified by DIN EN ISO 9000 ff in numerous areas.
Struthweg 7 - 9 34260 Kaufungen Deutschland ,
(Germany)

Inctech Metrology Center

(American Association for Laboratory Accreditation)

Inctech Metrological Center Co.,Ltd.39/1 Sukhapiban 5 Rd., Soi 82, Orngoen, Saimai   Bangkok   10220   (Thailand)